skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Cryogenically cooled monochromators for the Advanced Photon Source

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1147509· OSTI ID:389533
 [1]
  1. Experimental Facilities Division, Advanced Photon Source, Argonne Naional Laboratory, Argonne, IL 60439 (United States)

The use of cryogenically cooled monochromators looks to be a very promising possibility for the Advanced Photon Source. This position has recently been bolstered by several experiments performed on beamlines at the ESRF and CHESS. At the ESRF, several crystal geometries have been tested that were designed for high power densities ({approx_gt}150 W/mm{sup 2}) and moderate total absorbed powers ({lt}200 W). These geometries have proven to be very successful at handling these power parameters with measured strains on the arc-second level. The experiments performed at CHESS were focused on high total power ({approx_gt}1000 W) but moderate power densities. As with the previously mentioned experiments, the crystals designed for this application performed superbly with no measurable broadening of the rocking curves on the arc-second level. These experiments will be summarized and, based on these results, the performance of cryogenic monochromators for the APS will be assessed. {copyright} {ital 1996 American Institute of Physics.}

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
389533
Report Number(s):
CONF-9510119-; ISSN 0034-6748; TRN: 96:027934
Journal Information:
Review of Scientific Instruments, Vol. 67, Issue 9; Conference: SRI `95: synchrotron radiation instrumentation symposium and the 7. users meeting for the advanced photon source (APS), Argonne, IL (United States), 16-20 Oct 1995; Other Information: PBD: Sep 1996
Country of Publication:
United States
Language:
English