Title: Why compton-suppressed germanium detector arrays?

Journal Article · · Bulletin of the American Physical Society
OSTI ID:386911
 [1]
  1. Lawrence Berkeley Laboratory, CA (United States)

Nuclear spectroscopic studies have provided a strong incentive to obtain {gamma}-ray detectors with increasingly better energy resolution, higher full-energy peak efficiencies, and greater sensitivity or resolving power. A major step was the introduction of Ge detectors in the early 60`s. But because of the low atomic number of Ge they have a poor response function; a majority of interacting gamma rays of moderate energy Compton scatter out of the detector leaving a large low-energy background. The remedy was to add a Compton-suppression shield made of NaI around the Ge crystal, and if interactions occurred simultaneously in the NaI scintillator and in the Ge detector to veto that event. Efficiencies also increased greatly when an English-Danish collaboration assembled five Ge detectors, each with a NaI suppressor, into the first array at the end of 1980. Obviously, a system of five such detectors gave much better statistics than the usual two bare detectors used for obtaining coincidence data (by a factor of 10). A few years later, another major improvement came with replacement of the NaI suppressors with shields made of the much denser bismuth germanate (BGO) as scintillator, as these could be thinner leading to arrays with of order 20 detectors. Use of such a large number of detectors led to the realization that for cascades of coincident gamma rays, as in going down a band, the improvement in the peak/background ratio observed and already appreciated in going from singles spectra to gated (double-) coincidence spectra continued when doubly-gated triple-coincidence data were compared for the first time to singly-gated double-coincidence ones. The higher-gated spectra were much cleaner and more selective, though with poorer statistics, and the advantages of higher folds and efficiencies led to the proposals for the larger 4{pi} arrays of today, Eurogam and GASP in Europe and Gammasphere in the U.S.

OSTI ID:
386911
Report Number(s):
CONF-931044-; ISSN 0003-0503; TRN: 96:026846
Journal Information:
Bulletin of the American Physical Society, Vol. 38, Issue 9; Conference: Fall meeting of the Division of Nuclear Physics of the American Physical Society, Pacific Grove, CA (United States), 20-23 Oct 1993; Other Information: PBD: Oct 1993
Country of Publication:
United States
Language:
English

Similar Records

Status of development of the Gamma Ray Energy Tracking Array (GRETA)
Conference · Tue Dec 31 00:00:00 EST 1996 · OSTI ID:386911

Compton suppression tests on Ge and BGO prototype detectors for gammasphere
Conference · Sat Aug 01 00:00:00 EDT 1992 · OSTI ID:386911

Bismuth germanate as a high-energy gamma-ray detector
Journal Article · Fri Apr 01 00:00:00 EST 1983 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:386911