Title: Some peculiarities of checking the Topaz-2 system coolant filling quality

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.49891· OSTI ID:385490
; ;  [1]
  1. Central Design Bureau of Machine Building (CDBMB), Krasnogvardeyskaya Square 3, St. Petersburg, Russia, 195272

This paper contains the analysis of validity of methods used for checking the Topaz-2 system coolant filling quality by a metering tank according to the mathematical model developed. A number of criteria is proposed for detecting occluded gas in the coolant loop. {copyright} {ital 1996 American Institute of Physics.}

OSTI ID:
385490
Report Number(s):
CONF-960109-; ISSN 0094-243X; TRN: 96:026249
Journal Information:
AIP Conference Proceedings, Vol. 361, Issue 1; Conference: STAIF 96: space technology and applications international forum, Albuquerque, NM (United States), 7-11 Jan 1996; Other Information: PBD: Mar 1996
Country of Publication:
United States