skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Combustion testing and heat recovery study: Frank E. Van Lare Wastewater Treatment Plant, Monroe County. Final report

Technical Report ·
OSTI ID:371079

The report describes the results of combustion testing work, and analysis of heat recovery and use at the Monroe County Frank E. Van Lare wastwater treatment plant (WWTP). The three multiple-hearth furnaces at the plant process an average of 65 dry tons of dewatered sludge per day. The furnaces use about 12.5 million Btus of natural gas per dry ton of sludge incinerated, or about 300 billion Btus per year. Center shaft and rabble arm cooling air is recirculated to the furnaces as pre-heated combustion air. No other heat from the combustion process is recovered for use in the plant. The project had four objectives: to record and analyze sludge management operations data and sludge incinerator combustion data; to ascertain instrumentation and control needs; to calculate heat balances for the incineration system; and to determine the feasibility of full waste-heat recovery and utilization, at the Frank E. Van Lare wastewater treatment plant.

Research Organization:
Pirnie (Malcolm), Inc., Rochester, NY (United States)
OSTI ID:
371079
Report Number(s):
PB-96-195078/XAB; TRN: 62392985
Resource Relation:
Other Information: PBD: Jan 1995
Country of Publication:
United States
Language:
English