Non-uniform composite representation of hydroelectric systems for long-term hydrothermal scheduling
Conference
·
OSTI ID:367427
- UNICAMP, Campinas, Sao Paulo (Brazil). Electrical Engineering Faculty
This paper presents a non-uniform composite representation of hydroelectric systems for use in long-term hydrothermal scheduling. This representation was developed from reservoir operational rules based on optimal reservoir trajectories obtained with a deterministic hydrothermal scheduling algorithm. A test system consisting of {tau} large hydroelectric plants of the Southeast Brazilian Power System with 12,572 MW of installed power capacity was selected for a case study. Operational cost comparisons with the classical uniform composite representation reveal significant savings.
- OSTI ID:
- 367427
- Report Number(s):
- CONF-950525-; TRN: IM9640%%173
- Resource Relation:
- Conference: IEEE power industry computer applications conference, Salt Lake City, UT (United States), 7-12 May 1995; Other Information: PBD: 1995; Related Information: Is Part Of 1995 IEEE power industry computer application conference: Proceedings; PB: 588 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Non-uniform composite representation of hydroelectric systems for long-term hydrothermal scheduling
An efficient hydrothermal scheduling algorithm
A large scale application of an optimal deterministic hydrothermal scheduling algorithm
Journal Article
·
Wed May 01 00:00:00 EDT 1996
· IEEE Transactions on Power Systems
·
OSTI ID:367427
An efficient hydrothermal scheduling algorithm
Journal Article
·
Sat Aug 01 00:00:00 EDT 1987
· IEEE Trans. Power Syst.; (United States)
·
OSTI ID:367427
A large scale application of an optimal deterministic hydrothermal scheduling algorithm
Journal Article
·
Thu Feb 01 00:00:00 EST 1990
· IEEE Transactions on Power Systems (Institute of Electrical and Electronics Engineers); (USA)
·
OSTI ID:367427