Title: Operation and maintenance of a new hazardous waste multi-purpose rotary kiln incinerator (system) in compliance with the Environmental Protection Agency and Louisiana (US) regulations

Conference ·
OSTI ID:353609
 [1]
  1. Novartis Crop Protection, Inc., Gabriel, LA (United States)

The proper management of hazardous and non-hazardous waste generated by modern society will continue to be a challenge for the world. Waste minimization and recycling practices will play a significant role in reducing the amount of waste to be managed. Total elimination of all waste in present day society is unlikely to occur in the future. Therefore, generators must take a proactive and responsible care approach to manage their wastes. An effective treatment operation to manage combustible waste is incineration. Properly designed, high efficiency waste incineration systems are very effective treatment solutions for waste management, particularly when compared to land disposal alternatives. High temperature incineration provides a permanent solution for destroying combustible waste and eliminate harmful or toxic organic constituents in the waste. The Novartis Crop Protection, Inc., St. Gabriel Facility, top environmental priority in the management of waste is to minimize waste at the source. The remaining wastes are recycled, detoxified, and/or incinerated. Land disposal of waste is the last resort for waste management. To achieve the St. Gabriel Facility waste management priorities, a new multi-purpose rotary kiln incinerator was constructed in 1992--93. The incinerator is the first of its kind constructed and permitted in the State of Louisiana since the promulgation of RCRA. The final operating conditions under RCRA were obtained from the regulatory agencies in 1996. This paper will discuss the operating and maintenance programs that were implemented for the new multi-purpose rotary kiln incinerator system to meet the RCRA permit conditions. A review of the preventative maintenance programs (i.e., equipment, monitors, analyzers), computer control, waste analysis, tracking of key parameters, operational cost and equipment reliability of the incinerator system will be presented.

OSTI ID:
353609
Report Number(s):
CONF-970677-; TRN: IM9929%%155
Resource Relation:
Conference: 90. annual meeting and exhibition of the Air and Waste Management Association, Toronto (Canada), 8-13 Jun 1997; Other Information: PBD: 1997; Related Information: Is Part Of 1997 proceedings of the Air and Waste Management Association`s 90. annual meeting and exhibition; PB: [7000] p.
Country of Publication:
United States
Language:
English

Similar Records

Marine shale and the Hazwaste recycling debate
Journal Article · Sat Oct 01 00:00:00 EDT 1988 · Hazmat World; (United States) · OSTI ID:353609

The Savannah River Plant Consolidated Incineration Facility
Conference · Thu Jan 01 00:00:00 EST 1987 · OSTI ID:353609

Hazardous waste combustion: Key judicial developments
Conference · Wed Dec 31 00:00:00 EST 1997 · OSTI ID:353609