skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Development of ASME performance test code 12.5, single phase heat exchangers

Conference ·
OSTI ID:320886
 [1];  [2]
  1. MPR Associates, Alexandria, VA (United States)
  2. Baltimore Gas and Electric Co., Lusby, MD (United States). Calvert Cliffs Nuclear Power Plant

Testing of heat exchanger performance is conducted to (1) confirm that the installed unit meets design specifications, (2) troubleshoot degradation, and (3) assess process improvements. Standard test methods are needed to ensure that highly accurate and reliable test results are obtained. These methods need to predict heat exchanger performance at design conditions based on test measurements at different conditions. ASME Performance Test Code 12.5, Single Phase Heat Exchangers, is under development to meet these needs. This paper summarizes the content of PTC 12.5 which is ready for industry review. The new PTC improves upon existing guidelines because methods to minimize and quantify uncertainty are provided. Overall uncertainty as low as 8% in heat transfer rate and overall heat transfer coefficient is possible for a well designed and properly instrumented thermal performance test.

OSTI ID:
320886
Report Number(s):
CONF-980426-; TRN: IM9910%%76
Resource Relation:
Conference: American power conference, Chicago, IL (United States), 14-16 Apr 1998; Other Information: PBD: 1998; Related Information: Is Part Of Proceedings of the American Power Conference: Volume 60-2; McBride, A.E. [ed.]; PB: 588 p.
Country of Publication:
United States
Language:
English