Addendum 2 to CSER 94-007 and CSER 94-008 Title: Burning one whole Pu button in muffle furnace in the HC-21C hood
This addendum reviews the current CPS` and their supporting CSERs for HC-21A and HC-21C Hoods and provides the criticality safety analysis for burning a whole Pu button in HC-21C.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 290514
- Report Number(s):
- WHC-SD-SQA-CSA-515; ON: DE98058506; BR: EW7003000; TRN: 96000833
- Resource Relation:
- Other Information: PBD: 24 Sep 1996
- Country of Publication:
- United States
- Language:
- English