Title: Evaluation of mine fires due to spontaneous combustion in the mechanized faces of Middle Anatolian Lignite mine (OAL), case studies

Conference ·
OSTI ID:269222

In this paper fires due to spontaneous combustion in Middle Anatolian Lignite mine (OAL) which is the first fully mechanized underground lignite mine in Turkey, are studied. Since the installation of mechanization, due to spontaneous heating, four panel fires namely, AO1, AO2, AO3 and AO4 have broken out. During these fires, the concentrations of carbon monoxide, methane and the velocity of air are measured continuously by the Micro Minos Environmental monitoring system. For each fire, the environment where fire has started is examined and the possible causes of the fire are investigated. Also the precautions taken to extinguish the fire at different stages are described and the importance of the early detection of mine fire are discussed together with the limitations of the monitoring system the practical difficulties observed during the fire.

OSTI ID:
269222
Report Number(s):
CONF-9506227-; TRN: 96:001467-0029
Resource Relation:
Conference: 7. U.S. mine ventilation symposium, Lexington, KY (United States), 5-7 Jun 1995; Other Information: PBD: 1995; Related Information: Is Part Of Proceedings of the 7th US mine ventilation symposium; Wala, A.M.; PB: 525 p.
Country of Publication:
United States
Language:
English