Title: Phase-sensitive optical coherence tomography-based vibrometry using a highly phase-stable akinetic swept laser source

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4939335· OSTI ID:22494502
; ;  [1];  [2]
  1. Department of Biomedical Engineering, Texas A&M University, College Station, Texas (United States)
  2. Department of Otolaryngology - Head and Neck Surgery, Stanford University, Stanford, California (United States)

Phase-sensitive Optical Coherence Tomography (PhOCT) is an emerging tool for in vivo investigation of the vibratory function of the intact middle and inner ear. PhOCT is able to resolve micron scale tissue morphology in three dimensions as well as measure picometer scale motion at each spatial position. Most PhOCT systems to date have relied upon the phase stability offered by spectrometer detection. On the other hand swept laser source based PhOCT offers a number of advantages including balanced detection, long imaging depths, and high imaging speeds. Unfortunately the inherent phase instability of traditional swept laser sources has necessitated complex user developed hardware/software solutions to restore phase sensitivity. Here we present recent results using a prototype swept laser that overcomes these issues. The akinetic swept laser is electronically tuned and precisely controls sweeps without any mechanical movement, which results in high phase stability. We have developed an optical fiber based PhOCT system around the akinetic laser source that had a 1550 nm center wavelength and a sweep rate of 140 kHz. The stability of the system was measured to be 4.4 pm with a calibrated reflector, thus demonstrating near shot noise limited performance. Using this PhOCT system, we have acquired structural and vibratory measurements of the middle ear in a mouse model, post mortem. The quality of the results suggest that the akinetic laser source is a superior laser source for PhOCT with many advantages that greatly reduces the required complexity of the imaging system.

OSTI ID:
22494502
Journal Information:
AIP Conference Proceedings, Vol. 1703, Issue 1; Conference: 12. international workshop on the mechanics of hearing, Cape Sounio (Greece), 23-29 Jun 2014; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English