skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SU-E-I-78: Establishing a Protocol for Quick Estimation of Thyroid Internal Contamination with 131I in Normal and Emergency Situations

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4924075· OSTI ID:22494020
 [1]; ;  [2]; ; ; ; ;  [3];  [4]
  1. Radiation Research Center, Shiraz university, Shiraz, Fars (Iran, Islamic Republic of)
  2. Radiation medicine department, school of mechanical engineering, Shiraz uni, Shiraz, Fars (Iran, Islamic Republic of)
  3. Shiraz University, Shiraz, Fars (Iran, Islamic Republic of)
  4. Shahid Beheshti University, Shiraz, Fars (Iran, Islamic Republic of)

Purpose: I-131 is one of the most frequent radionuclides used in nuclear medicine departments. The radiation workers, who manipulate the unsealed radio-toxic iodine, should be monitored for internal contamination. In this study a protocol was established for estimating I-131 activity absorbed in the thyroid glands of the nuclear medicine staff in normal working condition and also in accidents. Methods: I-131 with the activity of 10 μCi was injected inside the thyroid gland of a home-made anthropomorphic neck phantom. The phantom is made up of PMMA as soft tissue, and Aluminium as bone. The dose rate at different distances from the surface of the neck phantom was measured using a scintillator detector for duration of two months. Then, calibration factors were obtained, for converting the dose rate at each distance to the iodine activity inside the thyroid. Results: According to the results of this study, the calibration factors for converting the dose rates (nSv/h) at distances of 0cm, 1cm, 6cm, 11cm, and 16cm to the activity (kBq) inside the thyroid were found to be 0.03, 0.04, 0.14, 0.29, and 0.49 . Conclusion: This method can be effectively used for quick estimation of the I-131 concentration inside the thyroid of the staff for daily checks in normal working conditions and also in accidents.

OSTI ID:
22494020
Journal Information:
Medical Physics, Vol. 42, Issue 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

STUDIES ON THYROID VOLUME BY SCINTILLATION SPECTROMETER
Journal Article · Sun Jan 01 00:00:00 EST 1961 · Proc. Japan Conf. Radioisotopes · OSTI ID:22494020

SU-E-I-24: Design and Fabrication of a Multi-Functional Neck and Thyroid Phantom for Medical Dosimetry and Calibration
Journal Article · Sun Jun 01 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22494020

Assessment of effective dose to staff in brachytherapy
Journal Article · Fri Nov 01 00:00:00 EST 1996 · Health Physics · OSTI ID:22494020