skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Vortex breakdown in closed containers with polygonal cross sections

Journal Article · · Physics of Fluids (1994)
DOI:https://doi.org/10.1063/1.4936764· OSTI ID:22482461
; ;  [1]
  1. Kutateladze Institute of Thermophysic SB RAS, Novosibirsk 630090 (Russian Federation)

The vortex breakdown bubble in the confined flow generated by a rotating lid in closed containers with polygonal cross sections was analysed both experimentally and numerically for the height/radius aspect ratio equal to 2. The stagnation point locations of the breakdown bubble emergence and the corresponding Reynolds number were determined experimentally and in addition computed numerically by STAR-CCM+ CFD software for square, pentagonal, hexagonal, and octagonal cross section configurations. The flow pattern and the velocity were observed and measured by combining the seeding particle visualization and the temporal accuracy of laser Doppler anemometry. The vortex breakdown size and position on the container axis were determined for Reynolds numbers, ranging from 1450 to 2400. The obtained results were compared with the flow structure in the closed container of cubical and cylindrical configurations. It is shown that the measured evolution of steady vortex breakdown is in close agreement with the numerical results.

OSTI ID:
22482461
Journal Information:
Physics of Fluids (1994), Vol. 27, Issue 12; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-6631
Country of Publication:
United States
Language:
English