KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s
Abstract
The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.
- Authors:
-
- Russian Federal Nuclear Center All-Russian Research Institute of Experimental Physics (Russian Federation)
- Research Institute of Materials Technology (Russian Federation)
- Publication Date:
- OSTI Identifier:
- 22471963
- Resource Type:
- Journal Article
- Journal Name:
- Physics of Atomic Nuclei
- Additional Journal Information:
- Journal Volume: 78; Journal Issue: 11; Other Information: Copyright (c) 2015 Pleiades Publishing, Ltd.; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 1063-7788
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 22 GENERAL STUDIES OF NUCLEAR REACTORS; DELAYED NEUTRONS; DOSE RATES; FISSION; GAMMA DETECTION; GAMMA RADIATION; NEUTRON DETECTION; NEUTRON DETECTORS; PROMPT NEUTRONS; REACTORS
Citation Formats
Koshelev, A. S., E-mail: alexsander.coshelev@yandex.ru, Dovbysh, L. Ye., Khoruzhy, V. Kh., and Chuklyaev, S. V. KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s. United States: N. p., 2015.
Web. doi:10.1134/S1063778815110083.
Koshelev, A. S., E-mail: alexsander.coshelev@yandex.ru, Dovbysh, L. Ye., Khoruzhy, V. Kh., & Chuklyaev, S. V. KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s. United States. https://doi.org/10.1134/S1063778815110083
Koshelev, A. S., E-mail: alexsander.coshelev@yandex.ru, Dovbysh, L. Ye., Khoruzhy, V. Kh., and Chuklyaev, S. V. 2015.
"KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s". United States. https://doi.org/10.1134/S1063778815110083.
@article{osti_22471963,
title = {KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s},
author = {Koshelev, A. S., E-mail: alexsander.coshelev@yandex.ru and Dovbysh, L. Ye. and Khoruzhy, V. Kh. and Chuklyaev, S. V.},
abstractNote = {The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.},
doi = {10.1134/S1063778815110083},
url = {https://www.osti.gov/biblio/22471963},
journal = {Physics of Atomic Nuclei},
issn = {1063-7788},
number = 11,
volume = 78,
place = {United States},
year = {Tue Dec 15 00:00:00 EST 2015},
month = {Tue Dec 15 00:00:00 EST 2015}
}
Other availability
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.