skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4905116· OSTI ID:22413430
 [1];  [2];  [3]
  1. Medical Technology Department, Radiological Sciences Center, Health Sciences Faculty, Tarapaca University, Arica 1000000 (Chile)
  2. Hemodynamic Department, Cardiovascular Service, Luis Calvo Mackenna Hospital, Santiago 7500539 (Chile)
  3. Radiology Department, Faculty of Medicine, Complutense University and IdIS, San Carlos Hospital, Madrid 28040 (Spain)

Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.

OSTI ID:
22413430
Journal Information:
Medical Physics, Vol. 42, Issue 2; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Pilot program on patient dosimetry in pediatric interventional cardiology in Chile
Journal Article · Tue May 15 00:00:00 EDT 2012 · Medical Physics · OSTI ID:22413430

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures
Journal Article · Fri Jun 15 00:00:00 EDT 2012 · Cardiovascular and Interventional Radiology · OSTI ID:22413430

Patient Dose Reference Levels for Interventional Radiology: A National Approach
Journal Article · Thu Jan 15 00:00:00 EST 2009 · Cardiovascular and Interventional Radiology · OSTI ID:22413430