Title: WE-G-17A-07: Investigation of the Influence of the Electron Return Effect (ERE) On the Dose Distribution in Rectal Cancer Patients On a 1.5T MR-Linac

Abstract

Purpose: The purpose of this planning study is to investigate the influence of the ERE on the day-to-day dose distribution in rectal cancer patients, where changes in gas-pockets frequently occur. Methods: Daily CT scans of 5 patients treated neo-adjuvant with 5x5Gy for rectal cancer were used. We optimized two plans on the planning CT (Monaco, 1 mm3 dosegrid), a conventional 7-field 6MV IMRT plan (Dconv) and a plan in the presence of a 1.5T field (Dmrl). We recalculated the plans on all repeat-CT scans and evaluated under/over-dosage of the daily CTVs. Changes of more than 1% were considered significant. In the bowel area, we investigated the relative dose changes due to the ERE, where the contribution of the ERE was separated from other effects such as attenuation. Results: Both plans were comparable and compliant with ICRU 62 for all patients. For 2 fractions in one patient under-dosage in the CTV was significant, due to a disappearing gas-pocket. Here the V95 was 96.82 and 97.36% in in Dmrl compared to 98.85 and 98.66% in Dconv, respectively. For 3 fractions in another patient appearing gas-pockets resulted in significant over-dosage of the CTV. In these fractions the V107 was 1.88–2.68% in Dmrl comparedmore » to 0.33–1.27% in Dconv. In the bowel area the dose changes attributable to the ERE were approximately ± 5% in 1cc, at low dose levels. Conclusion: We were able to calculate acceptable treatment plans with and without a magnetic field. The ERE was present in the Dmrl, but the volumetric effect within the CTV was limited. Outside the CTV relative dose differences were similar, but on small volumes at lower, less relevant dose levels. This suggests that there is no clinical relevant ERE on dose distributions in rectal cancer patients on a 1.5T MR-Linac.« less

Authors:
; ;  [1];  [2];  [3]
  1. NKI, Amsterdam, Zuid Holland (Netherlands)
  2. Netherlands Cancer Institute, Amsterdam (Netherlands)
  3. Elekta, Inc, Verona, WI (Italy)
Publication Date:
OSTI Identifier:
22409764
Resource Type:
Journal Article
Journal Name:
Medical Physics
Additional Journal Information:
Journal Volume: 41; Journal Issue: 6; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 0094-2405
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; CAT SCANNING; LINEAR ACCELERATORS; NEOPLASMS; PATIENTS; PLANNING; RADIATION DOSE DISTRIBUTIONS; RECTUM

Citation Formats

Uilkema, S, Heide, U, Nijkamp, J, Sonke, J, and Moreau, M. WE-G-17A-07: Investigation of the Influence of the Electron Return Effect (ERE) On the Dose Distribution in Rectal Cancer Patients On a 1.5T MR-Linac. United States: N. p., 2014. Web. doi:10.1118/1.4889509.
Uilkema, S, Heide, U, Nijkamp, J, Sonke, J, & Moreau, M. WE-G-17A-07: Investigation of the Influence of the Electron Return Effect (ERE) On the Dose Distribution in Rectal Cancer Patients On a 1.5T MR-Linac. United States. https://doi.org/10.1118/1.4889509
Uilkema, S, Heide, U, Nijkamp, J, Sonke, J, and Moreau, M. 2014. "WE-G-17A-07: Investigation of the Influence of the Electron Return Effect (ERE) On the Dose Distribution in Rectal Cancer Patients On a 1.5T MR-Linac". United States. https://doi.org/10.1118/1.4889509.
@article{osti_22409764,
title = {WE-G-17A-07: Investigation of the Influence of the Electron Return Effect (ERE) On the Dose Distribution in Rectal Cancer Patients On a 1.5T MR-Linac},
author = {Uilkema, S and Heide, U and Nijkamp, J and Sonke, J and Moreau, M},
abstractNote = {Purpose: The purpose of this planning study is to investigate the influence of the ERE on the day-to-day dose distribution in rectal cancer patients, where changes in gas-pockets frequently occur. Methods: Daily CT scans of 5 patients treated neo-adjuvant with 5x5Gy for rectal cancer were used. We optimized two plans on the planning CT (Monaco, 1 mm3 dosegrid), a conventional 7-field 6MV IMRT plan (Dconv) and a plan in the presence of a 1.5T field (Dmrl). We recalculated the plans on all repeat-CT scans and evaluated under/over-dosage of the daily CTVs. Changes of more than 1% were considered significant. In the bowel area, we investigated the relative dose changes due to the ERE, where the contribution of the ERE was separated from other effects such as attenuation. Results: Both plans were comparable and compliant with ICRU 62 for all patients. For 2 fractions in one patient under-dosage in the CTV was significant, due to a disappearing gas-pocket. Here the V95 was 96.82 and 97.36% in in Dmrl compared to 98.85 and 98.66% in Dconv, respectively. For 3 fractions in another patient appearing gas-pockets resulted in significant over-dosage of the CTV. In these fractions the V107 was 1.88–2.68% in Dmrl compared to 0.33–1.27% in Dconv. In the bowel area the dose changes attributable to the ERE were approximately ± 5% in 1cc, at low dose levels. Conclusion: We were able to calculate acceptable treatment plans with and without a magnetic field. The ERE was present in the Dmrl, but the volumetric effect within the CTV was limited. Outside the CTV relative dose differences were similar, but on small volumes at lower, less relevant dose levels. This suggests that there is no clinical relevant ERE on dose distributions in rectal cancer patients on a 1.5T MR-Linac.},
doi = {10.1118/1.4889509},
url = {https://www.osti.gov/biblio/22409764}, journal = {Medical Physics},
issn = {0094-2405},
number = 6,
volume = 41,
place = {United States},
year = {Sun Jun 15 00:00:00 EDT 2014},
month = {Sun Jun 15 00:00:00 EDT 2014}
}