Title: SU-E-T-439: An Improved Formula of Scatter-To-Primary Ratio for Photon Dose Calculation

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4888772· OSTI ID:22369734
 [1]
  1. University Pennsylvania, Philadelphia, PA (United States)

Purpose: Scatter-to-primary ratio (SPR) is an important dosimetric quantity that describes the contribution from the scatter photons in an external photon beam. The purpose of this study is to develop an improved analytical formula to describe SPR as a function of circular field size (r) and depth (d) using Monte Carlo (MC) simulation. Methods: MC simulation was performed for Mohan photon spectra (Co-60, 4, 6, 10, 15, 23 MV) using EGSNRC code. Point-spread scatter dose kernels in water are generated. The scatter-to-primary ratio (SPR) is also calculated using MC simulation as a function of field size for circular field size with radius r and depth d. The doses from forward scatter and backscatter photons are calculated using a convolution of the point-spread scatter dose kernel and by accounting for scatter photons contributing to dose before (z'd) reaching the depth of interest, d, where z' is the location of scatter photons, respectively. The depth dependence of the ratio of the forward scatter and backscatter doses is determined as a function of depth and field size. Results: We are able to improve the existing 3-parameter (a, w, d0) empirical formula for SPR by introducing depth dependence for one of the parameter d0, which becomes 0 for deeper depths. The depth dependence of d0 can be directly calculated as a ratio of backscatter-to-forward scatter doses for otherwise the same field and depth. With the improved empirical formula, we can fit SPR for all megavoltage photon beams to within 2%. Existing 3-parameter formula cannot fit SPR data for Co-60 to better than 3.1%. Conclusion: An improved empirical formula is developed to fit SPR for all megavoltage photon energies to within 2%.

OSTI ID:
22369734
Journal Information:
Medical Physics, Vol. 41, Issue 6; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

SU-F-J-12: Dosimetrical Characteristics of a 2.5 MV Megavoltage Photon Beam
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22369734

Backscatter correction factor for megavoltage photon beam
Journal Article · Sat Oct 15 00:00:00 EDT 2011 · Medical Physics · OSTI ID:22369734

Physical approach to depth dose distributions in a water phantom irradiated by a teleisotope photon beam
Journal Article · Sat Mar 01 00:00:00 EST 1980 · Med. Phys.; (United States) · OSTI ID:22369734