Title: Influence of wick properties in a vertical LHP on remove waste heat from electronic equipment

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4892738· OSTI ID:22308416
; ;  [1]
  1. University of Žilina, Faculty of Mechanical Engineering, Department of Power Engeneering, Univerzitna 1, 010 26 Žilina (Slovakia)

The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work is to develop porous wick of sintered nickel powder with different grain sizes. These porous wicks were used in LHP and there were performed a series of measurements to remove waste heat from the insulated gate bipolar transistor (IGBT)

OSTI ID:
22308416
Journal Information:
AIP Conference Proceedings, Vol. 1608, Issue 1; Conference: 19. international conference on the application of experimental and numerical methods in fluid mechanics and energetics 2014, Liptovsky Jan (Slovakia), 9-11 Apr 2014; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X