skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX

Abstract

Dosimetric data for a brachytherapy source should be known before it used for clinical treatment. Iridium-192 source type H01 was manufactured by PRR-BATAN aimed to brachytherapy is not yet known its dosimetric data. Radial dose function and anisotropic dose distribution are some primary keys in brachytherapy source. Dose distribution for Iridium-192 source type H01 was obtained from the dose calculation formalism recommended in the AAPM TG-43U1 report using MCNPX 2.6.0 Monte Carlo simulation code. To know the effect of cavity on Iridium-192 type H01 caused by manufacturing process, also calculated on Iridium-192 type H01 if without cavity. The result of calculation of radial dose function and anisotropic dose distribution for Iridium-192 source type H01 were compared with another model of Iridium-192 source.

Authors:
 [1]
  1. Center for development of nuclear informatics, National Nuclear Energy Agency, PUSPIPTEK, Serpong, Banten 15310 (Indonesia)
Publication Date:
OSTI Identifier:
22307866
Resource Type:
Journal Article
Journal Name:
AIP Conference Proceedings
Additional Journal Information:
Journal Volume: 1615; Journal Issue: 1; Conference: ICANSE 2013: 4. international conference on advances in nuclear science and engineering, Denpasar, Bali (Indonesia), 16-19 Sep 2013; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 0094-243X
Country of Publication:
United States
Language:
English
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; 62 RADIOLOGY AND NUCLEAR MEDICINE; ANISOTROPY; BRACHYTHERAPY; COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; IRIDIUM 192; M CODES; MONTE CARLO METHOD; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES

Citation Formats

Purwaningsih, Anik. Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX. United States: N. p., 2014. Web. doi:10.1063/1.4895890.
Purwaningsih, Anik. Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX. United States. https://doi.org/10.1063/1.4895890
Purwaningsih, Anik. 2014. "Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX". United States. https://doi.org/10.1063/1.4895890.
@article{osti_22307866,
title = {Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX},
author = {Purwaningsih, Anik},
abstractNote = {Dosimetric data for a brachytherapy source should be known before it used for clinical treatment. Iridium-192 source type H01 was manufactured by PRR-BATAN aimed to brachytherapy is not yet known its dosimetric data. Radial dose function and anisotropic dose distribution are some primary keys in brachytherapy source. Dose distribution for Iridium-192 source type H01 was obtained from the dose calculation formalism recommended in the AAPM TG-43U1 report using MCNPX 2.6.0 Monte Carlo simulation code. To know the effect of cavity on Iridium-192 type H01 caused by manufacturing process, also calculated on Iridium-192 type H01 if without cavity. The result of calculation of radial dose function and anisotropic dose distribution for Iridium-192 source type H01 were compared with another model of Iridium-192 source.},
doi = {10.1063/1.4895890},
url = {https://www.osti.gov/biblio/22307866}, journal = {AIP Conference Proceedings},
issn = {0094-243X},
number = 1,
volume = 1615,
place = {United States},
year = {Tue Sep 30 00:00:00 EDT 2014},
month = {Tue Sep 30 00:00:00 EDT 2014}
}