skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Wireless Monitoring Study in the Meuse / Haute-Marne Underground Research Laboratory, France - 12046

Conference ·
OSTI ID:22293383
; ;  [1]; ;  [2]; ;  [3]
  1. Radioactive Waste Management Funding and Research Center - RWMC (Japan)
  2. National Radioactive Waste Management Agency - ANDRA (France)
  3. Kajima Corporation (Japan)

Two types of wireless transmission systems using ultra low frequency (8.5 kHz) were developed and used in the Callovo-Oxfordian argillites layer in the Meuse / Haute-Marne Underground Research Laboratory (CMHM URL) in France. Short-range and mid-range transmission antennas received data transmitted from 25 m to 50 m away. From the results of two series of tests, it is clear that transmission is practical when the received voltage is larger than the received noise. However, it is also clear that wireless transmission in the CMHM URL gallery is affected by the electromagnetic noise level and steel components, and the maximum transmission distance depends on the S/N ratio. The mid-range transmission antenna achieved a transmission distance of 240 m in the surface test, where the electromagnetic noise level was small and there was no environmental attenuation. The short-range transmission antenna achieved a transmission distance of 25 m in the surface test and in the CMHM URL gallery. As the clay layer of the CMHM URL had little effect on the attenuation of the electromagnetic field, transmission over 200 m might be possible in the CMHM URL when the electromagnetic noise level is small enough and there are no significant factors enhancing attenuation. But in reality, the possible transmission distance was around 50 m. In order to show the transmitter's ability, it is preferable to keep some distance between steel components and the transmitter. The most effective way to use this transmitter is to put it in a borehole drilled from a gallery to outside of a gallery around 10 m length. In this way, it might be possible to avoid almost of all the influence of steel components. For the position of receiver, the recommendation is the same as for the transmitter. That is, place the receiver where the incoming signal from the transmitter suffers little attenuation from steel components. Therefore, the option of implementing a receiving antenna in a borehole is required. (authors)

Research Organization:
WM Symposia, 1628 E. Southern Avenue, Suite 9-332, Tempe, AZ 85282 (United States)
OSTI ID:
22293383
Report Number(s):
INIS-US-14-WM-12046; TRN: US14V1036114907
Resource Relation:
Conference: WM2012: Waste Management 2012 conference on improving the future in waste management, Phoenix, AZ (United States), 26 Feb - 1 Mar 2012; Other Information: Country of input: France; 5 refs.
Country of Publication:
United States
Language:
English