Title: Operating characteristics of a new ion source for KSTAR neutral beam injection system

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4827682· OSTI ID:22254013
; ; ; ;  [1]
  1. Department of Nuclear Fusion Engineering Development, Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of)

A new positive ion source for the Korea Superconducting Tokamak Advanced Research neutral beam injection (KSTAR NBI-1) system was designed, fabricated, and assembled in 2011. The characteristics of the arc discharge and beam extraction were investigated using hydrogen and helium gas to find the optimum operating parameters of the arc power, filament voltage, gas pressure, extracting voltage, accelerating voltage, and decelerating voltage at the neutral beam test stand at the Korea Atomic Energy Research Institute in 2012. Based on the optimum operating condition, the new ion source was then conditioned, and performance tests were primarily finished. The accelerator system with enlarged apertures can extract a maximum 65 A ion beam with a beam energy of 100 keV. The arc efficiency and optimum beam perveance, at which the beam divergence is at a minimum, are estimated to be 1.0 A/kW and 2.5 uP, respectively. The beam extraction tests show that the design goal of delivering a 2 MW deuterium neutral beam into the KSTAR Tokamak plasma is achievable.

OSTI ID:
22254013
Journal Information:
Review of Scientific Instruments, Vol. 85, Issue 2; Conference: ICIS 2011: 14. international conference on ion sources, Giardini-Naxos, Sicily (Italy), 12-16 Sep 2011; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

First neutral beam injection experiments on KSTAR tokamak
Journal Article · Wed Feb 15 00:00:00 EST 2012 · Review of Scientific Instruments · OSTI ID:22254013

New ion source for KSTAR neutral beam injection system
Journal Article · Wed Feb 15 00:00:00 EST 2012 · Review of Scientific Instruments · OSTI ID:22254013

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector
Journal Article · Sat Feb 15 00:00:00 EST 2014 · Review of Scientific Instruments · OSTI ID:22254013