Title: Parallel double-plate capacitive proximity sensor modelling based on effective theory

Journal Article · · AIP Advances
DOI:https://doi.org/10.1063/1.4866986· OSTI ID:22251225
; ; ;  [1]
  1. Research Center for Non-destructive Testing and Evaluation, Beijing University of Technology, Beijing100124 (China)

A semi-analytical model for a double-plate capacitive proximity sensor is presented according to the effective theory. Three physical models are established to derive the final equation of the sensor. Measured data are used to determine the coefficients. The final equation is verified by using measured data. The average relative error of the calculated and the measured sensor capacitance is less than 7.5%. The equation can be used to provide guidance to engineering design of the proximity sensors.

OSTI ID:
22251225
Journal Information:
AIP Advances, Vol. 4, Issue 2; Other Information: (c) 2014 Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 2158-3226