skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4851595· OSTI ID:22250922
; ; ;  [1];  [2]
  1. Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States)
  2. Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

OSTI ID:
22250922
Journal Information:
Medical Physics, Vol. 41, Issue 1; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation
Journal Article · Wed Jan 15 00:00:00 EST 2014 · Medical Physics · OSTI ID:22250922

TH-C-17A-09: Direct Visualization and Monitoring of Medical Radiation Beams in Air
Journal Article · Sun Jun 15 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22250922

Selection of techniques for orthovoltage radiation therapy
Journal Article · Tue May 01 00:00:00 EDT 1990 · International Journal of Radiation Oncology, Biology and Physics; (USA) · OSTI ID:22250922