Title: Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4849195· OSTI ID:22250750
; ; ; ; ;  [1];  [2]
  1. Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan (China)
  2. Department of Physics, Katholieke Universiteit Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium)

Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm × 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min.

OSTI ID:
22250750
Journal Information:
Review of Scientific Instruments, Vol. 84, Issue 12; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English