Observations of soft X-ray emission and plasma dynamics of a compact capillary discharge operated in xenon
- Facultad de Física, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago (Chile)
We report observations of a low stored energy, low inductance compact capillary discharge operated in xenon. Even though the stored electrical energy is less than 1 J, significant output in the optical windows at 110 and 135 Å is measured. The soft X-ray emission is time-resolved and the conversion energy of the source is obtained. A lower bound to the conversion efficiency at 110 Å ± 2% and 135 Å ± 1% of 3.6% and 1.6% is obtained, respectively. The use of moiré-schlieren optical diagnostic allows the evolution of the line electron density. In particular, we observe a significant degree of compression in a tight on axis pinch as well as radial compression waves. The temporal evolution of the X-ray emission, which occurs during the current reversal and later, is discussed in relation to work in argon discharges and in relation to model calculations.
- OSTI ID:
- 22220631
- Journal Information:
- Physics of Plasmas, Vol. 20, Issue 9; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-664X
- Country of Publication:
- United States