Title: Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

Journal Article · · Medical Dosimetry
; ;  [1];  [2]
  1. Department of Radiation Oncology, Institut Curie, Paris (France)
  2. Department of Anesthesiology and Reanimation, Institut Curie, Paris (France)

To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

OSTI ID:
22130403
Journal Information:
Medical Dosimetry, Vol. 37, Issue 2; Other Information: Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0958-3947
Country of Publication:
United States
Language:
English

Similar Records

Proton Beam Therapy Interference With Implanted Cardiac Pacemakers
Journal Article · Sat Nov 01 00:00:00 EDT 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22130403

Has the Pattern of Practice in the Prescription of Radiotherapy for the Palliation of Thoracic Symptoms Changed Between 1999 and 2006 at the Rapid Response Radiotherapy Program?
Journal Article · Sat Mar 01 00:00:00 EST 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22130403

Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators