skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Impact of variable RBE on proton fractionation

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4769417· OSTI ID:22099166
;  [1]
  1. Department of Radiation Physics UHL, County Council of Oestergoetland, 581 85 Linkoeping (Sweden) and Radiation Physics, Department of Medical and Health Sciences, Faculty of Health Sciences, Linkoeping University, 581 83 Linkoeping (Sweden)

Purpose: To explore the impact of variable proton relative biological effectiveness (RBE) on dose fractionation for clinically relevant situations. A generic RBE = 1.1 is generally used for isoeffect calculations, while experimental studies showed that proton RBE varies with tissue type, dose, and linear energy transfer (LET). Methods: An analytical expression for the LET and {alpha}/{beta} dependence of the linear-quadratic (LQ) model has been used for proton simulations in parallel with the assumption of a generic RBE = 1.1. Calculations have been performed for ranges of LET values and fractionation sensitivities to describe clinically relevant cases, such as the treatment of head and neck and prostate tumors. Isoeffect calculations were compared with predictions from a generic RBE value and reported clinical results. Results: The generic RBE = 1.1 appears to be a reasonable estimate for the proton RBE of rapidly growing tissues irradiated with low LET radiation. However, the use of a variable RBE predicts larger differences for tissues with low {alpha}/{beta} (both tumor and normal) and at low doses per fraction. In some situations these differences may appear in contrast to the findings from photon studies highlighting the importance of accurate accounting for the radiobiological effectiveness of protons. Furthermore, the use of variable RBE leads to closer predictions to clinical results. Conclusions: The LET dependence of the RBE has a strong impact on the predicted effectiveness of fractionated proton radiotherapy. The magnitude of the effect is modulated by the fractionation sensitivity and the fractional dose indicating the need for accurate analyses both in the target and around it. Care should therefore be employed for changing clinical fractionation patterns or when analyzing results from clinical studies for this type of radiation.

OSTI ID:
22099166
Journal Information:
Medical Physics, Vol. 40, Issue 1; Other Information: (c) 2013 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English