Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging
- Kobe City College of Technology, 8-3 Gakuen-Higashi-machi, Nishi-ku, Kobe 651-2194 (Japan)
Purpose: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd{sub 2}SiO{sub 5} (GSO) block with a high quantum efficiency PSPMT. Methods: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm x 1.9 mm x 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 x 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). Results: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was {approx}15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was {approx}0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. Conclusions: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.
- OSTI ID:
- 22098751
- Journal Information:
- Medical Physics, Vol. 39, Issue 2; Other Information: (c) 2012 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
- Country of Publication:
- United States
- Language:
- English
Similar Records
Optimization of a mini-gamma camera based on a 2?2 array of Hamamatsu H8500 PSPMTs
Portable gamma camera for clinical use in nuclear medicine
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
CERIUM ADDITIONS
COBALT 57
COLLIMATORS
DOPED MATERIALS
ENERGY RESOLUTION
EQUIPMENT
GADOLINIUM COMPOUNDS
GAMMA CAMERAS
GAMMA RADIATION
KEV RANGE 100-1000
NATURAL RADIOACTIVITY
PHANTOMS
PHOSPHORS
PHOTOMULTIPLIERS
QUANTUM EFFICIENCY
SPATIAL RESOLUTION
TWO-DIMENSIONAL CALCULATIONS