Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study
- Radiation Medicine Program, Princess Margaret Hospital, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)
Purpose: The impact of photon beam energy and tissue heterogeneities on dose distributions and dosimetric characteristics such as point dose, mean dose, and maximum dose was investigated in the context of small-animal irradiation using Monte Carlo simulations based on the EGSnrc code. Methods: Three Monte Carlo mouse phantoms, namely, heterogeneous, homogeneous, and bone homogeneous were generated based on the same mouse computed tomography image set. These phantoms were generated by overriding the tissue type of none of the voxels (heterogeneous), all voxels (homogeneous), and only the bone voxels (bone homogeneous) to that of soft tissue. Phase space files of the 100 and 225 kVp photon beams based on a small-animal irradiator (XRad225Cx, Precision X-Ray Inc., North Branford, CT) were generated using BEAMnrc. A 360 deg. photon arc was simulated and three-dimensional (3D) dose calculations were carried out using the DOSXYZnrc code through DOSCTP in the above three phantoms. For comparison, the 3D dose distributions, dose profiles, mean, maximum, and point doses at different locations such as the isocenter, lung, rib, and spine were determined in the three phantoms. Results: The dose gradient resulting from the 225 kVp arc was found to be steeper than for the 100 kVp arc. The mean dose was found to be 1.29 and 1.14 times higher for the heterogeneous phantom when compared to the mean dose in the homogeneous phantom using the 100 and 225 kVp photon arcs, respectively. The bone doses (rib and spine) in the heterogeneous mouse phantom were about five (100 kVp) and three (225 kVp) times higher when compared to the homogeneous phantom. However, the lung dose did not vary significantly between the heterogeneous, homogeneous, and bone homogeneous phantom for the 225 kVp compared to the 100 kVp photon beams. Conclusions: A significant bone dose enhancement was found when the 100 and 225 kVp photon beams were used in small-animal irradiation. This dosimetric effect, due to the presence of the bone heterogeneity, was more significant than that due to the lung heterogeneity. Hence, for kV photon energies of the range used in small-animal irradiation, the increase of the mean and bone dose due to the photoelectric effect could be a dosimetric concern.
- OSTI ID:
- 22096789
- Journal Information:
- Medical Physics, Vol. 37, Issue 10; Other Information: (c) 2010 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
- Country of Publication:
- United States
- Language:
- English
Similar Records
SU-E-T-285: Dose Variation at Bone in Small-Animal Irradiation: A Monte Carlo Study Using Monoenergetic Photon Beams
Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
60 APPLIED LIFE SCIENCES
ACCURACY
BIOLOGICAL RADIATION EFFECTS
COMPUTERIZED SIMULATION
COMPUTERIZED TOMOGRAPHY
DOSIMETRY
IMAGES
IRRADIATION
LUNGS
MICE
MONTE CARLO METHOD
PHANTOMS
PHASE SPACE
PHOTOELECTRIC EFFECT
PHOTON BEAMS
PHOTONS
RADIATION DOSE DISTRIBUTIONS
RADIATION DOSES
RADIOTHERAPY
VERTEBRAE
X RADIATION