Title: Respiratory motion management in particle therapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3250856· OSTI ID:22096618
;  [1]
  1. Abteilung Biophysik, GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstrasse 1, 64291 Darmstadt (Germany) and Siemens Healthcare Sector, Workflow and Solutions, Particle Therapy, Hofmannstrasse 26, 91052 Erlangen (Germany)

Clinical outcomes of charged particle therapy are very promising. Currently, several dedicated centers that use scanning beam technology are either close to clinical use or under construction. Since scanned beam treatments of targets that move with respiration most likely result in marked local over- and underdosage due to interplay of target motion and dynamic beam application, dedicated motion mitigation techniques have to be employed. To date, the motion mitigation techniques, rescanning, beam gating, and beam tracking, have been proposed and tested in experimental studies. Rescanning relies on repeated irradiations of the target with the number of particles reduced accordingly per scan to statistically average local misdosage. Specific developments to prohibit temporal correlation between beam scanning and target motion will be required to guarantee adequate averaging. For beam gating, residual target motion within gating windows has to be mitigated in order to avoid local misdosage. Possibly the most promising strategy is to increase the overlap of adjacent particle pencil beams laterally as well as longitudinally to effectively reduce the sensitivity against small residual target motion. The most conformal and potentially most precise motion mitigation technique is beam tracking. Individual particle pencil beams have to be adapted laterally as well as longitudinally according to the target motion. Within the next several years, it can be anticipated that rescanning as well as beam gating will be ready for clinical use. For rescanning, treatment planning margins that incorporate the full extent of target motion as well as motion induced density variations in the beam paths will result in reduced target conformity of the applied dose distributions. Due to the limited precision of motion monitoring devices, it seems likely that beam gating will be used initially to mitigate interplay effects only but not to considerably decrease treatment planning margins. Then, in the next step, beam gating, based on more accurate motion monitoring systems, provides the possibility to restore target conformity as well as steep dose gradients due to reduced treatment planning margins. Accurate motion monitoring systems will be required for beam tracking. Even though beam tracking has already been successfully tested experimentally, full clinical implementation requires direct feedback of the actual target position in quasireal time to the treatment control system and can be anticipated to be several more years ahead.

OSTI ID:
22096618
Journal Information:
Medical Physics, Vol. 37, Issue 2; Other Information: (c) 2010 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy
Journal Article · Fri Mar 15 00:00:00 EDT 2013 · Medical Physics · OSTI ID:22096618

Gated Irradiation With Scanned Particle Beams
Journal Article · Sun Mar 15 00:00:00 EDT 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22096618

Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment
Journal Article · Tue Oct 01 00:00:00 EDT 2013 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22096618