skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Optima MDxt: A high throughput 335 keV mid-dose implanter

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4766558· OSTI ID:22075717

The continuing demand for both energy purity and implant angle control along with high wafer throughput drove the development of the Axcelis Optima MDxt mid-dose ion implanter. The system utilizes electrostatic scanning, an electrostatic parallelizing lens and an electrostatic energy filter to produce energetically pure beams with high angular integrity. Based on field proven components, the Optima MDxt beamline architecture offers the high beam currents possible with singly charged species including arsenic at energies up to 335 keV as well as large currents from multiply charged species at energies extending over 1 MeV. Conversely, the excellent energy filtering capability allows high currents at low beam energies, since it is safe to utilize large deceleration ratios. This beamline is coupled with the >500 WPH capable endstation technology used on the Axcelis Optima XEx high energy ion implanter. The endstation includes in-situ angle measurements of the beam in order to maintain excellent beam-to-wafer implant angle control in both the horizontal and vertical directions. The Optima platform control system provides new generation dose control system that assures excellent dosimetry and charge control. This paper will describe the features and technologies that allow the Optima MDxt to provide superior process performance at the highest wafer throughput, and will provide examples of the process performance achievable.

OSTI ID:
22075717
Journal Information:
AIP Conference Proceedings, Vol. 1496, Issue 1; Conference: 19. international conference on ion implantation technology, Valladolid (Spain), 25-29 Jun 2012; Other Information: (c) 2012 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Process Performance of Optima XEx Single Wafer High Energy Implanter
Journal Article · Fri Jan 07 00:00:00 EST 2011 · AIP Conference Proceedings · OSTI ID:22075717

Optima XE Single Wafer High Energy Ion Implanter
Journal Article · Mon Nov 03 00:00:00 EST 2008 · AIP Conference Proceedings · OSTI ID:22075717

Optima HD Imax: Molecular Implant
Journal Article · Mon Nov 03 00:00:00 EST 2008 · AIP Conference Proceedings · OSTI ID:22075717