skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Targeted Endovascular Temporary Vessel Occlusion with a Reverse Thermosensitive Polymer for Near-Bloodless Partial Nephrectomy: Comparison to Standard Surgical Clamping Techniques

Journal Article · · Cardiovascular and Interventional Radiology
 [1]; ; ;  [2];  [3];  [4];  [5]; ;  [2]
  1. Lahey Clinic, Tuft University Medical School, Department of Radiology (United States)
  2. Lahey Clinic, Tuft University Medical School, Department of Urology (United States)
  3. Pluromed Inc (United States)
  4. DaVinci Biomedical Research Products (United States)
  5. Lahey Clinic, Tuft University Medical School, Department of Pathology (United States)

Purpose: To determine whether reversible blood flow interruption to a randomly chosen target region of the kidney may be achieved with the injection of a reverse thermoplastic polymer through an angiographic catheter, thereby facilitating partial nephrectomy without compromising blood flow to the remaining kidney or adding risks beyond those encountered by the use of hilar clamping. Methods: Fifteen pigs underwent partial nephrectomy after blood flow interruption by vascular cross-clamping or injection of polymer (Lumagel Trade-Mark-Sign ) into a segmental artery. Five animals were euthanized after surgery (three open and two laparoscopic resection, cross-clamping n = 2), and 10 (open resection, cross-clamping n = 4) were euthanized after 6 weeks' survival. Blood specimens were obtained periodically, and angiogram and necropsy were performed at 6 weeks. Results: Selective renal ischemia was achieved in all cases. Surgical resection time averaged 9 and 24.5 min in the open and laparoscopic groups, respectively. Estimated blood loss was negligible with the exception of one case where an accessory renal artery was originally overlooked. Reversal of the polymer to a liquid state was consistent angiographically and visually in all cases. Time to complete flow return averaged 7.4 and 2 min for polymer and clamping, respectively. Angiography at 6 weeks revealed no evidence of vascular injury. Laboratory data and necropsies revealed no differences between animals undergoing vascular clamping or polymer injection. Conclusion: Lumagel was as effective as vascular clamping in producing a near bloodless operative field for partial nephrectomy while maintaining flow to the uninvolved portion of the affected kidney.

OSTI ID:
22066539
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 35, Issue 5; Other Information: Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English