Title: Note: Studies on x-ray production in electron cyclotron resonance x-ray source based on ridged cylindrical cavity

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3687020· OSTI ID:22063807
;  [1]
  1. Radiological Safety Division, Indira Gandhi Center for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)

A ridged cylindrical cavity has been designed using MICROWAVE STUDIO programme and it is used in the electron cyclotron resonance (ECR) x-ray source. The experimental parameters of the source are optimized for maximizing the x-ray output, and an x-ray dose rate of {approx}1000 {mu}Sv/h was observed at 20 cm from the port, for 500 W of microwave power without using any target. With the molybdenum target located at optimum position of the ridged cavity, the dose rate is found to be increased only by 10%. In order to understand the experimental observation, the electric field pattern of the cavity with the target placed at various radial distances is studied. In this note, the experimental and theoretical studies on ECR x-ray source using the ridged cylindrical cavity are presented.

OSTI ID:
22063807
Journal Information:
Review of Scientific Instruments, Vol. 83, Issue 2; Other Information: (c) 2012 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English