Title: Neutron spectrometry with He-3 proportional counters

Conference ·
; ; ;  [1];  [2];  [1]
  1. School of Physics, Aristotle Univ. of Thessaloniki, Thessaloniki 541 24, Hellas (Greece)
  2. Philipps-Universitaet, Marburg 35032 (Germany)

Helium filled proportional counters are widely used in the field of neutron detection and spectrometry. In this work the response of a commercially available He-3 counter is studied experimentally and calculated with Monte Carlo for the neutron energy range from 230 keV up to about 7 MeV. The calculated response of the system is used to determine neutron yield energy distribution emitted from an extended {sup nat}U/Pb assembly irradiated with 1.6 GeV deuterons. The results are in acceptable agreement with the calculated neutron distribution with DCM-DEM code. (authors)

OSTI ID:
22039865
Resource Relation:
Conference: ANIMMA 2011: 2. International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications, Ghent (Belgium), 6-9 Jun 2011; Other Information: Country of input: France; 17 refs.; IEEE Catalog Number: CFP1124I-CDR
Country of Publication:
United States
Language:
English

Similar Records

Nonlinearity of pulse height of recoil helium in {sup 3}He proportional counters
Journal Article · Sat Feb 01 00:00:00 EST 1997 · IEEE Transactions on Nuclear Science · OSTI ID:22039865

Measurement of {gamma}-ray dose in a thermal neutron field by using a {sup 3}He-filtered GM counter
Journal Article · Sat Jun 01 00:00:00 EDT 1996 · IEEE Transactions on Nuclear Science · OSTI ID:22039865

Neutron response functions improved by taking into consideration measured edge effect of [sup 3]He proportional counter