Production and test of isotopically modified Ge detectors for GERDA
Abstract
The viability of producing BEGe-type detectors from isotopically modified germanium for the GERDA experiment is demonstrated by a complete test of the supply chain. GERDA is built to search for neutrinoless double beta (0v{beta}{beta}) decay of Ge using high-purity germanium detectors made of material enriched in {sup 76}Ge. To reach a sensitivity for 0v{beta}{beta} decay of <1.4 x 10{sup 26} years, new active background suppression techniques are necessary. BEGe detectors enable a capability to efficiently identify and reject background events, while keeping large acceptance of 0v{beta}{beta} decay signal, by using novel pulse shape discrimination (PSD) techniques. The PSD as well as spectroscopic performance of prototype BEGe detectors from isotopically modified Ge was verified by comprehensive testing. (authors)
- Authors:
-
- Physik-Dept. E15, Technishe Universitaet Muenchen, James-Franck-Strasse 1, Garching bei Muenchen, D-85748 (Germany)
- Publication Date:
- OSTI Identifier:
- 22039796
- Resource Type:
- Conference
- Resource Relation:
- Conference: ANIMMA 2011: 2. International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications, Ghent (Belgium), 6-9 Jun 2011; Other Information: Country of input: France; 10 refs.; IEEE Catalog Number: CFP1124I-CDR
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; DECAY; GERMANIUM; GERMANIUM 76; HIGH-PURITY GE DETECTORS; PULSE SHAPERS; SENSITIVITY; SIGNALS; TESTING
Citation Formats
Budjas, D. Production and test of isotopically modified Ge detectors for GERDA. United States: N. p., 2011.
Web. doi:10.1109/ANIMMA.2011.6172864.
Budjas, D. Production and test of isotopically modified Ge detectors for GERDA. United States. https://doi.org/10.1109/ANIMMA.2011.6172864
Budjas, D. 2011.
"Production and test of isotopically modified Ge detectors for GERDA". United States. https://doi.org/10.1109/ANIMMA.2011.6172864.
@article{osti_22039796,
title = {Production and test of isotopically modified Ge detectors for GERDA},
author = {Budjas, D},
abstractNote = {The viability of producing BEGe-type detectors from isotopically modified germanium for the GERDA experiment is demonstrated by a complete test of the supply chain. GERDA is built to search for neutrinoless double beta (0v{beta}{beta}) decay of Ge using high-purity germanium detectors made of material enriched in {sup 76}Ge. To reach a sensitivity for 0v{beta}{beta} decay of <1.4 x 10{sup 26} years, new active background suppression techniques are necessary. BEGe detectors enable a capability to efficiently identify and reject background events, while keeping large acceptance of 0v{beta}{beta} decay signal, by using novel pulse shape discrimination (PSD) techniques. The PSD as well as spectroscopic performance of prototype BEGe detectors from isotopically modified Ge was verified by comprehensive testing. (authors)},
doi = {10.1109/ANIMMA.2011.6172864},
url = {https://www.osti.gov/biblio/22039796},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Jul 01 00:00:00 EDT 2011},
month = {Fri Jul 01 00:00:00 EDT 2011}
}