Title: Impact of Stent Design on In-Stent Stenosis in a Rabbit Iliac Artery Model

Journal Article · · Cardiovascular and Interventional Radiology
;  [1];  [2]; ;  [1];  [3];  [4]; ; ;  [1]
  1. University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)
  2. University Hospital Heidelberg, Department of General, Visceral and Transplantation Surgery (Germany)
  3. University Hospital Cologne, Department of Diagnostic Radiology (Germany)
  4. University Hospital Heidelberg, Department of Pathology (Germany)

The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury, vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.

OSTI ID:
21428984
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 33, Issue 3; Other Information: DOI: 10.1007/s00270-009-9757-6; Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); ISSN 0174-1551
Country of Publication:
United States
Language:
English