Title: Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ;  [1];  [2]
  1. National Cancer Center Hospital, Division of Diagnostic Radiology (Japan)
  2. Kobe University Hospital, Department of Radiology (Japan)

The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurred in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.

OSTI ID:
21428917
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 33, Issue 5; Other Information: DOI: 10.1007/s00270-010-9841-y; Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Percutaneous implantation of a Port-Catheter System using the left subclavian artery
Journal Article · Sat Jan 15 00:00:00 EST 2000 · Cardiovascular and Interventional Radiology · OSTI ID:21428917

Percutaneous Implantation of a Port-Catheter System Using the Left Subclavian Artery
Journal Article · Sat Jan 15 00:00:00 EST 2000 · Cardiovascular and Interventional Radiology · OSTI ID:21428917

Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis
Journal Article · Thu Dec 15 00:00:00 EST 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21428917