skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.3463375· OSTI ID:21410369
 [1];  [2]; ; ; ; ;  [2]; ;  [3];  [2];  [2];  [4];  [1]; ;  [5]
  1. RIKEN SPring-8 Center, Harima Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)
  2. Japan Science and Technology Agency, CREST, 5 Sanban-cho, Chiyoda-ku, Tokyo 102-0075 (Japan)
  3. JASRI/SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)
  4. Graduate School of Pure and Applied Sciences, University of Tsukuba, Tennodai, Tsukuba, Ibaraki 305-8571 (Japan)
  5. Candox Systems Inc., 15-21, Oshiage-cho, Gyoda, Saitama 361-0045 (Japan)

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

OSTI ID:
21410369
Journal Information:
AIP Conference Proceedings, Vol. 1234, Issue 1; Conference: SRI 2009: 10. international conference on radiation instrumentation, Melbourne (Australia), 27 Sep - 2 Oct 2009; Other Information: DOI: 10.1063/1.3463375; (c) 2010 American Institute of Physics; ISSN 0094-243X
Country of Publication:
United States
Language:
English