Title: Interfractional Uncertainty in the Treatment of Pancreatic Cancer With Radiation

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
;  [1];  [2];  [3]; ;  [1]
  1. Department of Radiation Oncology, Stanford University, Stanford, CA (United States)
  2. Division of Gastroenterology, Stanford University, Stanford, CA (United States)
  3. Department of Surgery, Stanford University, Stanford, CA (United States)

Purpose: To compare the interfractional variation in pancreatic tumor position using bony anatomy and implanted fiducial markers. Methods and Materials: Five consecutively treated patients with pancreatic adenocarcinoma who received definitive intensity-modulated radiation therapy at Stanford University (Stanford, CA) underwent fiducial seed placement and treatment on the Varian Trilogy system (Varian, Palo Alto, CA) with respiratory gating. Daily orthogonal kilovoltage imaging was performed to verify patient positioning, and isocenter shifts were made initially to match bony anatomy. Next, a final shift to the fiducial seeds was made under fluoroscopic guidance to confirm the location of the pancreatic tumor during the respiratory gated phase. All shifts were measured along three axes, left (+)-right (-), anterior (-)-posterior (+), and superior (+)-inferior (-), and the overall interfractional tumor movement was calculated based on these values. Results: A total of 140 fractions were analyzed. The mean absolute shift to fiducial markers after shifting to bony anatomy was 1.6 mm (95th percentile, 7 mm; range, 0-9 mm), 1.8 mm (95th percentile, 7 mm; range, 0-13 mm), and 4.1 mm (95th percentile, 12 mm; range, 0-19 mm) in the anterior-posterior, left-right, and superior-inferior directions, respectively. The mean interfractional vector shift distance was 5.5 mm (95th percentile, 14.5 mm; range, 0-19.3 mm). In 28 of 140 fractions (20%) no fiducial shift was required after alignment to bony anatomy. Conclusions: There is substantial residual uncertainty after alignment to bony anatomy when radiating pancreatic tumors using respiratory gating. Bony anatomy matched tumor position in only 20% of the radiation treatments. If bony alignment is used in conjunction with respiratory gating without implanted fiducials, treatment margins need to account for this uncertainty.

OSTI ID:
21372079
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 76, Issue 2; Other Information: DOI: 10.1016/j.ijrobp.2009.06.029; PII: S0360-3016(09)00940-7; Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; ISSN 0360-3016
Country of Publication:
United States
Language:
English