Title: A role of hydrocarbon reaction for NO{sub x} formation and reduction in fuel-rich pulverized coal combustion

Journal Article · · Combustion and Flame
; ; ; ;  [1]
  1. Energy and Environmental Systems Laboratory, Hitachi, Ltd. Power Systems Company, 7-2-1 Omika-cho, Hitachi-shi, Ibaraki-ken 319-1292 (Japan)

We have investigated an index for modeling a NO{sub x} reaction mechanism of pulverized coal combustion. The reaction mechanism of coal nitrogen was examined by drop-tube furnace experiments under various burning conditions. We proposed the gas phase stoichiometric ratio (SRgas) as a key index to evaluate NO{sub x} concentration in fuel-rich flames. The SRgas was defined as: SRgas {identical_to} amount of fuel required for stoichiometry combustion/amount of gasified fuel where, the amount of gasified fuel was defined as the amount of fuel which had been released to the gas phase by pyrolysis, oxidation and gasification reactions. When SRgas < 1.0, NO{sub x} concentration was strongly influenced by the value of SRgas. In this condition, the NO{sub x} concentration was hardly influenced by coal type, particle diameter, or reaction time. We developed a model to analyze NO{sub x} and XN(HCN, NH{sub 3}) concentrations for pulverized coal/air combustion and coal/CO{sub 2}/O{sub 2} combustion, based on the index. NO{sub x} and XN concentrations did not reproduce the experimental results without considering reactions between hydrocarbons and NO{sub x}. The hydrocarbon reaction was important for both NO{sub x} and XN, especially for air combustion. In the present model, an empirical formula was used to estimate the total concentration of hydrocarbons in coal flame. The reaction of heavy hydrocarbons which had plural aromatic rings was very important to analyze the reaction mechanism of hydrocarbons for coal combustion in detail. When burning temperature and SRgas were the same, total hydrocarbon concentration in a coal flame was larger than that of a light gaseous hydrocarbon flame. Total hydrocarbon concentration in oxy-fuel combustion was lower than that in air combustion. We verified the proposed model by experimental results obtained for a drop-tube furnace and a laboratory-scale furnace that had an installed low-NO{sub x} burner. (author)

OSTI ID:
21331450
Journal Information:
Combustion and Flame, Vol. 157, Issue 8; Other Information: Elsevier Ltd. All rights reserved; ISSN 0010-2180
Country of Publication:
United States
Language:
English