Transition edge sensor (TES)-based gamma ray detectors have been developed primarily for use up to energies of {approx}100 keV. However, there are many interesting applications at higher energies. We have started to develop a TES gamma-ray detector to apply to Positron Annihilation Spectroscopy analysis at 511 keV. Our detector is composed of a bulk lead absorber, which is coupled to a thin-film TES using a small amount of epoxy. The response of our first detector showed a very long decay tail of {approx}135 ms. To improve the device response time we have designed a new detector in which the response time is improved by a factor of five.

OSTI ID:
21325792
Journal Information:
AIP Conference Proceedings, Vol. 1185, Issue 1; Conference: LTD13: 13. international workshop on low temperature detectors, Stanford, CA (United States), 20-24 Jul 2009; Other Information: DOI: 10.1063/1.3292316; (c) 2009 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X