skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Changes in Prostate Shape and Volume and Their Implications for Radiotherapy After Introduction of Endorectal Balloon as Determined by MRI at 3T

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [3];  [1]
  1. Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  2. Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  3. Department of Urology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)

Purpose: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. Methods and materials: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T with a body array coil and subsequently with an ERC inflated with 50 mL of fluid. Prospectively, two experienced readers independently evaluated all data sets in random order. The maximal anteroposterior, right-to-left, and craniocaudal prostate diameters, as well as the total prostate and peripheral zone and central gland volumes were measured before and after ERC introduction. The changes in prostate shape and volume were analyzed using Wilcoxon's test for paired samples. Results: The introduction of the ERC significantly changed the prostate shape in all three directions, with mean changes in the anteroposterior, right-to-left, and craniocaudal diameters of 15.7% (5.5 mm), 7.7% (3.5 mm), and 6.3% (2.2 mm), respectively. The mean total prostate, peripheral zone, and central gland volume decreased significantly after ERC introduction by 17.9% (8.3 cm{sup 3}), 21.6% (4.8 cm{sup 3}), and 14.2% (3.4 cm{sup 3}), respectively. Conclusion: ERC introduction as observed by 3T MRI changed the prostate shape and volume significantly. The mean anteroposterior diameter was reduced by nearly one-sixth of its original diameter, and the mean total prostate volume was decreased by approximately 18%. This could cause difficulties and should be considered when using ERC-based MRI for MRI-computed tomography fusion and radiotherapy planning.

OSTI ID:
21276742
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 73, Issue 5; Other Information: DOI: 10.1016/j.ijrobp.2008.06.1491; PII: S0360-3016(08)02467-X; Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English