Title: Analyzing indirect secondary electron contrast of unstained bacteriophage T4 based on SEM images and Monte Carlo simulations

Journal Article · · Biochemical and Biophysical Research Communications

The indirect secondary electron contrast (ISEC) condition of the scanning electron microscopy (SEM) produces high contrast detection with minimal damage of unstained biological samples mounted under a thin carbon film. The high contrast image is created by a secondary electron signal produced under the carbon film by a low acceleration voltage. Here, we show that ISEC condition is clearly able to detect unstained bacteriophage T4 under a thin carbon film (10-15 nm) by using high-resolution field emission (FE) SEM. The results show that FE-SEM provides higher resolution than thermionic emission SEM. Furthermore, we investigated the scattered electron area within the carbon film under ISEC conditions using Monte Carlo simulation. The simulations indicated that the image resolution difference is related to the scattering width in the carbon film and the electron beam spot size. Using ISEC conditions on unstained virus samples would produce low electronic damage, because the electron beam does not directly irradiate the sample. In addition to the routine analysis, this method can be utilized for structural analysis of various biological samples like viruses, bacteria, and protein complexes.

OSTI ID:
21255913
Journal Information:
Biochemical and Biophysical Research Communications, Vol. 380, Issue 2; Other Information: DOI: 10.1016/j.bbrc.2009.01.046; PII: S0006-291X(09)00084-9; Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0006-291X
Country of Publication:
United States
Language:
English

Similar Records

A high contrast method of unstained biological samples under a thin carbon film by scanning electron microscopy
Journal Article · Fri Dec 05 00:00:00 EST 2008 · Biochemical and Biophysical Research Communications · OSTI ID:21255913

Nanoscale analysis of unstained biological specimens in water without radiation damage using high-resolution frequency transmission electric-field system based on FE-SEM
Journal Article · Fri Apr 10 00:00:00 EDT 2015 · Biochemical and Biophysical Research Communications · OSTI ID:21255913

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM
Journal Article · Fri Aug 07 00:00:00 EDT 2009 · Biochemical and Biophysical Research Communications · OSTI ID:21255913