Title: The calibration and monitoring system for the PHENIX lead-scintillator electromagnetic calorimeter

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.56957· OSTI ID:21199326

A system for calibrating the PHENIX lead-scintillator electromagnetic calorimeter modules with cosmic rays and monitoring the stability during operation is described. The system is based on a UV laser which delivers light to each module through a network of optical fibers and splitters and is monitored at various points with silicon and vacuum photodiodes. Results are given from a prototype system which used a nitrogen laser to set the initial phototube gains and to establish the energy calibration of calorimeter modules and monitor their stability. A description of the final system to be used in PHENIX, based on a high power YAG laser, is also given.

OSTI ID:
21199326
Journal Information:
AIP Conference Proceedings, Vol. 450, Issue 1; Conference: SCIFI97: 3. conference on scintillating and fiber detectors, Notre Dame, IN (United States), 2-6 Nov 1997; Other Information: DOI: 10.1063/1.56957; (c) 1998 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English