Study on drywell cooler applicability to severe accident management
Conference
·
OSTI ID:21160572
- Information and manufacturing systems division, Toshiba Plant Systems and Services Corporation, 8, Shinsugita-cho, Isogo-ku, Yokohama, 235-8523 (Japan)
- Power and Industrial Systems R and D Center, Toshiba Corporation, 4-1 Ukishima-cho, Kawasaki-ku, Kawasaki, 210-0862 (Japan)
- Isogo Nuclear Engineering Center, Toshiba Corporation, 8, Shinsugita-cho, Isogo-ku, Yokohama, 235-8523 (Japan)
- Nuclear Power Engineering Department, Tokyo Electric Power Company, 1-3 Uchisaiwai-cho 1-chome, Chiyoda-ku, Tokyo 100-0011 (Japan)
- Nuclear Plant Engineering Department, HITACHI, Ltd., 1-1, Saiwai-cho, 3-chome, Hitachi-shi, Ibaraki-ken, 317-8511 (Japan)
This paper concerns applicability of drywell cooler (DWC) heat removal under severe accident condition in BWR plants. Newly developed heat removal models based on DWC heat removal experiments were built into the MAAP3 code. And then, two types of Japanese BWR were selected to evaluate DWC heat removal performance under typical severe accident scenarios. According to the results of the evaluation, DWC delays or prevents containment failure or venting. (authors)
- Research Organization:
- American Nuclear Society, 555 North Kensington Avenue, La Grange Park, IL 60526 (United States)
- OSTI ID:
- 21160572
- Resource Relation:
- Conference: ICAPP'04: 2004 international congress on advances in nuclear power plants, Pittsburgh, PA (United States), 13-17 Jun 2004; Other Information: Country of input: France; 5 refs; Related Information: In: Proceedings of the 2004 international congress on advances in nuclear power plants - ICAPP'04, 2338 pages.
- Country of Publication:
- United States
- Language:
- English
Similar Records
System Integral Test by BWR Drywell Cooler Applied as Phase-II Accident Management
Steady Heat Removal Test by BWR Drywell Cooler under Accident Management Conditions
Containment venting as an accident management strategy
Conference
·
Mon Jul 01 00:00:00 EDT 2002
·
OSTI ID:21160572
+2 more
Steady Heat Removal Test by BWR Drywell Cooler under Accident Management Conditions
Conference
·
Mon Jul 01 00:00:00 EDT 2002
·
OSTI ID:21160572
+2 more
Containment venting as an accident management strategy
Conference
·
Fri Jan 01 00:00:00 EST 1988
·
OSTI ID:21160572