skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Decontamination of the Shaft no.1 and cleaning container of 2. block NPP Paks

Conference ·
OSTI ID:21156536
;  [1];  [2]
  1. VUJE Trnava, Inc. (Slovakia)
  2. NPP Paks PA Zrt. (Hungary)

Available in abstract form only. Full text of publication follows: Meanwhile cleaning fuel assemblies on Paks NPP Unit 2. in 2003 year, the fuel assemblies were damaged, followed by contamination of cleaning container and operating shaft No. 1., in which was the container. As a part of the task - to restore operation NPP Paks, Unit 2, VUJE and.. realized decontamination of the wall of shaft prior to withdrawal of the defected fuel, decontamination of cleaning tank and in consequence decontamination of full shaft No. 1. Solution rest at finished conceptual decontamination proposal, fabrication of special purpose furnished, necessary documentation according to national legislative exigency. Real facilities on decontamination were examined on the stand and on shaft No. 1 in real conditions. This paper describes access method decontaminating procedure, applied facilities assigned on decontamination and present achievement results from decontamination shaft No. 1 realized in August 2006 and February 2007, respectively. Decontamination procedures were chosen on the base of experiments realized in laboratories VUJE and in Paks NPP. Laboratory experiments were realized on the sample of tube used for measurement of neutron flow, from NPP Paks, located in the shaft No.1 in time of event (INES-3). In NPP Paks were realized experiments on cover of cleaning container, which was in time of event situated on cleaning container. To compare decontaminated factors, the chemical and electrochemical procedures for decontamination were tested, and most effective practices were selected. Equipment ROS-740 can be used for the top part of the shaft decontamination. It allows high-pressure admission, rinse and chemical decontamination. Manipulator MAOS-170 is assigned for high-pressure admission of central part of the shaft. (authors)

Research Organization:
American Society of Mechanical Engineers (ASME), Three Park Avenue, New York, NY 10016-5990 (United States); Technological Institute of the Royal Flemish Society of Engineers (TI-K VIV), Het Ingenieurshuis, Desguinlei 214, 2018 Antwerp (Belgium); Belgian Nuclear Society (BNS) - ASBL-VZW, c/o SCK-CEN, Avenue Hermann Debrouxlaan, 40 - B-1160 Brussels (Belgium)
OSTI ID:
21156536
Resource Relation:
Conference: ICEM'07: 11. International Conference on Environmental Remediation and Radioactive Waste Management, Bruges (Belgium), 2-6 Sep 2007; Other Information: Country of input: France; Proceedings may be ordered from ASME Order Department, 22 Law Drive, P.O. Box 2300, Fairfield, NJ 07007-2300 (United States)
Country of Publication:
United States
Language:
English