Title: On the effectiveness of smart technologies in the seismic protection of existing buildings Part II: Reinforced concrete structures

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2963812· OSTI ID:21148958
; ;  [1]
  1. Department of Civil Engineering, Second University of Naples Real Casa dell'Annunziata, via Roma 29 - Aversa (Italy)

The second part of a study concerning innovative intervention techniques for seismic protection of existing buildings is presented in this paper. The case of an existing framed r.c. structure, not designed for horizontal forces and extremely vulnerable to seismic action, is analyzed both in terms of maximum response reduction and energy dissipation. The proposed intervention approach, based on steel braces linked to the existing structure by passive or smart devices comes out appropriate and effective in the case of this type of buildings. The adopted control strategy produces a significant reducing effect on the elastic strain energy transmitted by the external perturbation to the structure, which is itself a fundamental safeguard aspect. The results prove the significantly improved capability of the system to dissipate input energy without structural damage, regardless of the specific seismic input.

OSTI ID:
21148958
Journal Information:
AIP Conference Proceedings, Vol. 1020, Issue 1; Conference: 2008 seismic engineering conference: Commemorating the 1908 Messina and Reggio Calabria earthquake, Reggio Calabria (Italy), 8-11 Jul 2008; Other Information: DOI: 10.1063/1.2963812; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English