skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Helical Tomotherapy Quality Assurance

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2]
  1. Department of Radiation Oncology, Mohawk Valley Medical Physics, Rome, NY (Italy)
  2. Department of Human Oncology, University of Wisconsin, Madison WI (United States)

Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed.

OSTI ID:
21124237
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 71, Issue 1; Conference: 2007 interorganizational symposium on quality assurance of radiation therapy: Challenges of advanced technology, Dallas, TX (United States), 20-22 Feb 2007; Other Information: DOI: 10.1016/j.ijrobp.2007.10.001; PII: S0360-3016(07)04295-2; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

QA for helical tomotherapy: Report of the AAPM Task Group 148
Journal Article · Wed Sep 15 00:00:00 EDT 2010 · Medical Physics · OSTI ID:21124237

WE-AB-201-00: Treatment Planning System Commissioning and QA
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:21124237

WE-AB-201-01: Treatment Planning System Commissioning and QA: Challenges and Opportunities
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:21124237