Performance of a Ge-microstrip imaging detector and polarimeter
Journal Article
·
· Review of Scientific Instruments
- Gesellschaft fuer Schwerionenforschung mbH, Planckstr. 1, 64291 Darmstadt (Germany)
- Department of Physics, University of Fribourg, CH-1700 Fribourg (Switzerland)
- Forschungszentrum Juelich GmbH, Institut fuer Kernphysik, 52425 Juelich (Germany)
Using 98% linearly polarized radiation at the European Synchrotron Radiation Facility in Grenoble, the performance of a prototype two-dimensional microstrip Ge(i) detector for x-ray imaging and as a Compton polarimeter has been evaluated. Using the energy and position sensitivity of the detector, the ability to obtain a complete reconstruction of the Compton event has been demonstrated. The modulation coefficient of the polarimeter is in good agreement with the theoretical limit of a perfect detector.
- OSTI ID:
- 21124103
- Journal Information:
- Review of Scientific Instruments, Vol. 79, Issue 8; Other Information: DOI: 10.1063/1.2963046; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
- Country of Publication:
- United States
- Language:
- English
Similar Records
Beam Test of a Prototype Phoswich Detector Assembly forthe PoGOLite Astronomical Soft Gamma-ray Polarimeter
Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype
Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty
Journal Article
·
Wed Jan 17 00:00:00 EST 2007
· Nuclear Instrumentation and Methods (NIM) A
·
OSTI ID:21124103
+16 more
Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype
Journal Article
·
Wed Oct 15 00:00:00 EDT 2008
· Journal of Applied Physics
·
OSTI ID:21124103
+9 more
Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty
Thesis/Dissertation
·
Fri May 01 00:00:00 EDT 2015
·
OSTI ID:21124103
Related Subjects
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
COMPTON EFFECT
EUROPEAN SYNCHROTRON RADIATION FACILITY
GE SEMICONDUCTOR DETECTORS
GERMANIUM
MODULATION
PERFORMANCE
POLARIMETERS
POSITION SENSITIVE DETECTORS
SEMICONDUCTOR MATERIALS
SENSITIVITY
TWO-DIMENSIONAL CALCULATIONS
X RADIATION
X-RAY DETECTION
COMPTON EFFECT
EUROPEAN SYNCHROTRON RADIATION FACILITY
GE SEMICONDUCTOR DETECTORS
GERMANIUM
MODULATION
PERFORMANCE
POLARIMETERS
POSITION SENSITIVE DETECTORS
SEMICONDUCTOR MATERIALS
SENSITIVITY
TWO-DIMENSIONAL CALCULATIONS
X RADIATION
X-RAY DETECTION