Title: Ion source for neutral beam injection meant for plasma and magnetic field diagnostics

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2802592· OSTI ID:21123679
; ; ; ;  [1]
  1. Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

At the Lawrence Berkeley National Laboratory a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The system is designed to have a 90% proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8x5 cm{sup 2}) extraction area. For this application, we have compared rf driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

OSTI ID:
21123679
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 2; Conference: ICIS 2007: 12. international conference on ion sources, Jeju (Korea, Republic of), 26-31 Aug 2007; Other Information: DOI: 10.1063/1.2802592; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748