Title: Experimental results of an electron cyclotron resonance oxygen source and a low energy beam transport system for 1 MeV integral split ring radio frequency quadruple accelerator upgrade project

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2802200· OSTI ID:21103991
; ; ; ; ; ; ; ;  [1]
  1. State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China)

To meet the requirements of developing separated function radio frequency quadruple (rfq) and upgrading the 1 MeV integral split ring rfq accelerator, an electron cyclotron resonance O{sup +} ion source and low energy beam transport (LEBT) system have been developed. Using two Einzel lenses to focus the beam, more than 6 mA O{sup +} peak beam current with energy of 22 keV can be easily obtained at the end of LEBT when the duty faction is at 1/6. The normalized root-mean-square emittance of 90% of the beam is about 0.12{pi} mm mrad. By changing the focusing power of lenses, the beam waist can be shifted from 80 mm before the beam diaphragm 2 to 80 mm after it. The experimental results will be presented in this article.

OSTI ID:
21103991
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 2; Conference: ICIS 2007: 12. international conference on ion sources, Jeju (Korea, Republic of), 26-31 Aug 2007; Other Information: DOI: 10.1063/1.2802200; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748